Learn Instrumentation, PLC, SCADA, DCS, Industrial Automation, Control System, etc.

Instrumentation ToolsInstrumentationTools
2026-02-07
Instrumentation ToolsInstrumentationTools
2026-02-07

A "Sinking" input card acts as a passive load to ground; it does not provide excitation voltage. Therefore, it requires a "4-Wire Active" transmitter (or a setup with an external power supply) that can "source" (push) the current into the card.

👇FOLLOW US👇

WhatsApp Channel: whatsapp.com/channel/0029VaAbU

Telegram Channel: t.me/+u3qORX5FKec1NjA1

Instrumentation ToolsInstrumentationTools
2026-02-07

Which AWG wire size would have the LOWEST electrical resistance for a long cable run?

Instrumentation ToolsInstrumentationTools
2026-02-06

Fish-feeding mechanism — PLC code example youtube.com/watch?v=zZE5cTr5nc8

Instrumentation ToolsInstrumentationTools
2026-02-06

If a fuse blows (opens), the circuit is broken, and current stops flowing. However, the potential difference (Voltage) from the power supply is still present at the break point. If you measure across the open fuse, you will read the full supply voltage (e.g., 24V), as the meter bridges the gap.

👇FOLLOW US👇

WhatsApp Channel: whatsapp.com/channel/0029VaAbU

Telegram Channel: t.me/+u3qORX5FKec1NjA1

Instrumentation ToolsInstrumentationTools
2026-02-06

Analog Value Comparison in PLC | Practical PLC Programming
youtube.com/watch?v=aoS0Ebm_yTM

Instrumentation ToolsInstrumentationTools
2026-02-06

A "Sinking" PLC Input card typically requires which type of connected device?

Instrumentation ToolsInstrumentationTools
2026-02-05

Siemens PLC Programming: Press Machine Safety Control
instrumentationtools.com/press

Instrumentation ToolsInstrumentationTools
2026-02-05

TIA Portal circuit-to-ladder logic conversion tutorial youtube.com/watch?v=zqOGPniidTo

Instrumentation ToolsInstrumentationTools
2026-02-05

"As-Found" data is the set of readings taken from the instrument before any adjustments or calibrations are made. This documents the drift or error state of the device since its last calibration. "As-Left" data is recorded after adjustments are completed.

👇FOLLOW US👇

WhatsApp Channel: whatsapp.com/channel/0029VaAbU

Telegram Channel: t.me/+u3qORX5FKec1NjA1

Instrumentation ToolsInstrumentationTools
2026-02-05
Instrumentation ToolsInstrumentationTools
2026-02-05

What is the voltage measured across an open fuse in a powered 4-20 mA standard loop?

Instrumentation ToolsInstrumentationTools
2026-02-04

Process Safety – Performance Key Point Aspects [I&C DESIGN]
instrumentationtools.com/proce

Instrumentation ToolsInstrumentationTools
2026-02-04

SCADA project archive/restore — WinCC youtube.com/watch?v=WPa78jen49A

Instrumentation ToolsInstrumentationTools
2026-02-04
Instrumentation ToolsInstrumentationTools
2026-02-04

A loop-powered indicator consumes no current (it passes the 4-20 mA through) but it "steals" voltage from the loop to power its display. This creates a voltage drop (typically 1V to 2.5V) that must be accounted for when calculating if the power supply can drive the total loop load.

👇FOLLOW US👇

WhatsApp Channel: whatsapp.com/channel/0029VaAbU

Telegram Channel: t.me/+u3qORX5FKec1NjA1

Instrumentation ToolsInstrumentationTools
2026-02-04

In calibration terms, "As-Found" data refers to:

Instrumentation ToolsInstrumentationTools
2026-02-03

SIL is Necessary for Process Safety, But is Not Sufficient
instrumentationtools.com/sil-i